Figure 5-11. Removal of combustion motor.
FUEL PUMP POWER SUPPLY

Maintenance Manual, Heater, Space, Multi-Fuel, With Blower, 6,000 Btu/Hr Page Navigation
  116    117    118    119    120  121  122    123    124    125    126  
img
. .
TM 5-4520-241-14
(2) Install motor housing (19) on motor (20) as shown in figure 5-12. Retain the motor housing to the motor by
staking the housing with a prick punch at three places around the joint. Seal notches with General Electric RTV-102, or
equivalent.
(3) Seal the housing-to-motor joint with tape before reinstalling in bottom motor housing assembly (13).
FIGURE 5-1
Figure 5-12. Combustion motor assembly relationships.
5-13.
VENTILATING MOTOR.
WARNING
This space heater contains dangerous voltages which can cause severe electrical
shock. Be sure to disconnect the power plug before repairing the heater.
a. Removal.
(1) Disconnect the orange and white leads from the ventilating motor at the terminal board and the electrical
connector, respectively.