TROUBLESHOOTING-CONTINUED
STEWART-WARNER 10560C24, 10560M, 10560M24B1, 10560G - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. HEATER OUTPUT TOO LOW
Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
Remove guard (page 2-42).
Clean and inspect fuel regulator valve (page 3-74).
Check restriction solenoid (1) as follows (10560C24, 10560G and 10560M only):
a.
b.
Check for
Start heater (page 2-59).
Using multimeter set for resistance, put red probe on terminal (2) and black
probe to good ground.
If multimeter reading is not 130-140 ohms, replace restriction solenoid (page
3-74).
proper fuel delivery during HI operation (10560C24, 10560G and 10560M,
page 3-84; 10560M24B1, page 3-96).
Adjust if necessary (page 3-84 and 3-96).
Remove and inspect burner assembly (malfunction 1), step 8.
Test heater (page 3-193).
a. It heater output is still too low, replace heater.
b. If heater output is normal, install guard (page 2-42).
3-16