TM 9-2540-205-24&P
RECEPTACLE CONNECTOR - HUPP MF510B, MF510C, MF60A-24V, MF50B-24V
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Personnel Required
Tool Kit, Mechanics Gen (Item 1, Appendix B)
63G
Equipment Condition
Guard removed (page 2-32)
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag all wires and terminals to aid durhg installation (page 2-3)
1, Flame detector switch (1)
Two screw assemblies (2)
Unscrew and remove.
and three leads (3)
3.
Control bracket assembly (1)
Screw assembly (2) and lead (3)
Unscrew and remove.
Terminal strip (4)
Two screw assemblies (5)
Unscrew and remove.
and three leads (6)
3-27
2.