TM 9-2540-205-24&P
RECEPTACLE CONNECTOR - HUPP MF510B, MF510C, MF60A-24V, MF60B-24V - Continued
LOCATION
ITEM
ACTION
REMARKS
REMOVAL - Continued
4. Control bracket assembly (1)
and receptacle connector (7)
5. Control bracket assembly (1)
INSTALLATION
6.
7.
8.
9.
Control bracket assembly (1)
Control bracket assembly (1)
and receptacle connector (7)
Terminal strip (4)
Control bracket assembly (1)
10. Flame detector switch (9)
Four screw assemblies (8)
Receptacle connector (7)
Receptacle connector (7)
Four screw assemblies (8)
Three leads (6) and two screw
assemblies (5)
Lead (3) and screw assembly (2)
Three leads (10) and two
screw assemblies (11 )
Unscrew and remove.
Unscrew and remove.
a. Feed wire leads under
terminal strip (9).
b. Install from behind
mounting lip of control
bracket assembly (l),
Screw in and tighten,
a.
b.
a.
b.
a.
b.
Install, noting tags made
during removal.
Screw in and tighten.
Place proper lead in position
noting tags made during
removal.
Screw in and tighten.
Install, noting tags made
during removal.
Screw in and tighten.
3-28