TM 9-2540-205-24&P
PULSED FUEL METERING VALVE - STEWART-WARNER 10560M24B1, 10560G - Continued
LOCATION
ITEM
ACTION
-
-
REMARKS
DISASSEMBLY - Continued
24. Valve body (1)
Valve core (2)
a. Unscrew and remove.
b. Discard.
25.
Bleeder valve (3)
Unscrew and remove.
26.
Four screws (4) and bracket (5)
Unscrew and remove.
27.
Elbow (6)
a. Place valve body (1) in vise
equipped with jaw caps.
b. Unscrew and remove.
c. Take valve body(1) out of vise.
CLEANING/inspection
28. Valve body (1)
29.
Nonmetal parts
Pulse generator (7)
a. Wipe clean with dry rags.
b. Look for signs of damage.
Replace if damaged.
a. Wipe clean with dry rags.
b. Look for cracks and chips in
coating.
The pulse generator
has a moisture resistant
coating. AppIy humi-
seaI to cracks and chips
in coating. PuIse
generator must give off
heat during operation,
and should not be
recoated more than one
time.
WARNlNG
Drycleaning solvent PD-680 is both toxic and flammable. Wear protective
goggles and gloves, and use only in well-venitlated area. Avoid contact with
skin, eyes, and clothes, and dont breathe vapors. Do not use near open flame
or excessive heat. The flashpoint is 100°F to 138°F (38°C to 59°C). if you
become dizzy while using dry cleaning solvent, get fresh air immediately, and
get medical aid. If contact with eyes is made, wash your eyes with water, and
get medical aid immediately.
3-92