TM 9-2540-205-24&P
THERMOSTATIC SWITCH (FLAME DETECTOR SWITCH) - STEWART-WARNER 10560C24, 10560M,
10560M24B1, 10560G - Contlnued
LOCATION
ITEM
ACTION
REMARKS
ADJUSTMENT
WARNING
Only adjust flame detector switch when heater is off and cool. Hot or operat-
ing heater can cause serious Injury to personnel.
The flame detector switch dose not control heater temperature. Misadjust-
ment of flame detector switch can cause damage to the heater and may result
In Injury to personnel.
CAUTION
Failure to apply sealant to screw wiII cause switch to go out of adjustment be-
cause of vibration. Tell operator to leave adjusting screw alone.
7. Flame detector switch (1)
Adjustment screw (6)
a. Unscrew partway.
b. Screw in until switch (1) clicks.
c. After switch (1) clicks, turn
l/2-turn clockwise.
d. Apply sealant.
NOTE
FOLLOW-ON MAINTENANCE: Install guard (page 2-42).
TASK ENDS HERE
2-44
WARNING