TM 9-4520-257-12&P 0011 00
0011 00-6
Table 2. Preventive Maintenance Checks and Services for H-45 Type II (Liquid Fuel) Heater-
Continued
Item
No.
Interval
Item To Be
Checked
Or
Serviced
Procedure
Equipment
Not Ready/
Available If:
11
During
Gravity Feed
Adapter (1)
Inspect adapter kit for missing or
defective parts.
Any fuel leaks. Kit damaged or
parts missing.
12
During
Hose
Assemblies
(2)
Inspect for cuts, punctures, and
serviceable fittings.
Any fuel leaks. Hose assemblies
damaged or fittings
unserviceable.
13
During
Stack Cap
Assembly (3)
Inspect tent lines, wire ropes for
damage.
Check cap for damage.
14
After
Top Heater
Shell and
Heater Body
Base (4)
Clean heater of foreign matter,
soot, or residue.
15
After
Burner Shell
Assembly (5)
Check for soot or residue
plugging burner holes.
Burner not clean.