TM 9-4520-257-12&P 0011 00
0011 00-2
NOTE
If the equipment must be kept in continuous operation, do only the
procedures that can be done without disturbing operation. Make
complete checks and services when the equipment is shut down.
Table 1. Preventive Maintenance Checks and Services for H-45 Type I (Solid Fuel) Heater-
Continued
Item
No.
Interval
Item To Be
Checked Or
Serviced
Procedure
Equipment
Not Ready/
Available If:
5
Before
Base Heater
Doors (5)
Inspect doors for alignment.
Doors do not open.
6
Before
Grate Heater
Doors (6)
Inspect doors for alignment.
Doors does not open.
7
Before
Stack Pipe
Assembly (7)
Inspect for dents. Clean soot.
Pipe sections bent out of shape
or do not fit together.
8
Before
Stack Cap
Assembly (8)
Inspect tent lines, wire ropes for
damage.
9
During
Spark
Arrester (2)
Inspect for snug fit and leaks.
Leaks.
10
During
Ashes and
Clinkers
Remove every 3 to 4 hours.
11
During
Stack Cap
Assembly (8)
Inspect tent lines, wire ropes for
damage.
12
After
Spark
Arrester (2)
Clean soot and residue as
required.
13
After
Top Heater
Shell and
Heater Body
Base (4)
Clean heater of foreign matter,
soot, or residue.