TM 9-4520-271-14
0017 00
PMCS
Continued
Table 1. Unit PMCS - Continued.
EQUIPMENT
NOT READY/
ITEM TO BE
AVAILABLE
CHECKED OR
ITEM
IF:
PROCEDURE
SERVICED
INTERVAL
NO.
INTERNAL - Continued
10
1,000 Hours
Heat Exchanger
Assembly
1.
Heat
1.
Inspect for loose or missing hardware.
Missing hard-
Exchanger
ware.
2.
Inspect for holes, cracks, other signs of burn-
Holes, cracks,
through or corrosion.
or signs of
burn-through.
3.
Inspect exhaust pipe for security, holes, cracks,
Any leaks.
other signs of exhaust leaks, or corrosion.
Dirty lens.
4.
Remove sight glass. Clean lens with wiping rag
and install on heat exchanger assembly.
2.
Ignition
1.
Inspect for loose or missing hardware. Tighten
Loose or miss-
loose hardware. Replace missing hardware
ing hardware.
2.
Inspect for loose connections, chafing, or exposed
Loose connec-
tions, chafing,
or exposed
wires.
0017 00-12