TM 9-4520-271-14
0019 00
CLEANING
1.
Clean air hose assembly (2) with a mild solution of general purpose detergent and water.
2.
Rinse thoroughly with clean water.
3.
Allow to dry completely.
INSPECTION
1.
Inspect clamps (1) for damaged screw head, deformed slots on strap, corrosion, and broken strap.
2.
Inspect air hose assembly (2) for rips, tears, and deterioration.
3.
Inspect air hose assembly (2) stiffener for bends and breaks.
REPAIR
1.
Patch small tears and holes with pressure sensitive tape.
2.
Replace air hose assembly (2) if clamps (1) are damaged or large tears or holes are present in fabric.
INSTALLATION
1.
Install air hose assembly (2) on ASH (3) with arrow facing direction of airflow.
2.
Install other end of air hose assembly (2) to shelter connector.
3.
Tighten clamp (1) on each end of air hose assembly (2) securely.
END OF WORK PACKAGE
0019 00-2