INSTALLATION
1.
Install O-ring (19) onto fitting (17).
2.
Install fitting (17) and nut (18).
3.
Insert power cable (15) through fitting (17).
4.
Route power cable (15) along bottom of ASH to clamp (14).
5.
Route cable (15) through clamp (14) and up through conduit (12). Allow enough slack to attach three wires to terminal
board TB1 (11) and ground stud (8). Tighten nut (13) and locking nut (16).
6.
Connect white wire P1-B↔TB1-2 and black wire P1-A↔TB1-1 to TB1 (11). Remove wire marker tags.
7.
Install lockwasher (10), green ground wire P1-C↔G (9) and remaining wires, ground stud (8), lockwasher (7), and nut
(6). Remove wire marker tags.
8.
Install wire ties as required
9.
Install wires (5), lockwasher (4), and nut (3).
WARNING
Acrylic lacquer sealant is flammable. Keep away from open flames or other sources of ignition. Avoid
breathing fumes from sealant. Good general ventilation is normally adequate. Avoid skin contact with
sealant.
10. Apply light coat of acrylic lacquer sealer to terminal board TB1 terminals and ground stud (8) connections.
11. Close side front door (2) and side rear door (1).