TM 9-4520-271-14
UNIT MAINTENANCE INSTRUCTIONS
ARMY SPACE HEATER H-140
WIRE LISTS
INTRODUCTION
This work package describes the wire lists for the ASH (Table 1) and the remote control box (Table 2). The wire lists are
used in conjunction with the ASH electrical system schematic diagram (Figure FO-1) during troubleshooting and repair. All
wiring information is provided, including wire gage, color, wire type by part number/specification, terminations, and wire
splice data.
ABBREVIATIONS
All abbreviations are in accordance with ASME Y14.38.
NOTES
1.
Wire colors are identified as follows:
0
6
Color Code
9
Second Tracer
0
Black
5
Green
For example, wire M5086/1-16-906
1
Brown
6
Blue
is a white wire with a black first
First Tracer
2
Red
7
Violet
tracer and a blue second tracer.
3
Orange
8
Gray
Base Color
4
Yellow
9
White
2.
Wire type, terminations, and splices listed in Tables 1 and 2 are described as follows:
K
=
Terminal lug, 12 GA, #10 stud, MS25036-112
A
=
Wire, M5086/1-18
L
=
Terminal lug, 12 GA, #1/4 stud, MS25036-157
B
=
Wire, M5086/1-16
M
=
Wire nut, electrical
C
=
Wire, M5086/1-12
N
=
Terminal, insulated quick-connect, female,
D
=
Terminal lug, 18 GA, #6 stud, MS 25036-102
MNV14-250DFI
E
=
Terminal lug, 18 GA, #1/4 stud, MS25036-150
O
=
Marker, heat shrinkable
F
=
Terminal lug, 16 GA, #6 stud, MS25036-106
P
=
Terminal, splice, crimp style
G
=
Terminal lug, 16 GA, #8 stud, MS25036-153
Q
=
Jumper, side-to-side
H
=
Terminal lug, 16 GA, #10 stud, MS25036-108
R
=
Jumper, deck-to-deck
I
=
Terminal lug, 16 GA, #1/4 stud, MS25036-154
S
=
Jumper, terminal board
J
=
Terminal lug, 12 GA, #8 stud, MS25036-156
3.
Polarity is indicated by POS or NEG.
4.
Each wire is marked with from/to terminal destinations.
5.
Part of cable assembly 60252-1.
0049 00-1