TM 9-4520-272-14&P
0002 00
EQUIPMENT DATA
The following technical and identification data pertains to the LCFH and its installation hardware.
Equipment Specification Data
Table 1. EQUIPMENT DATA.
Manufacturer
Hunter Manufacturing Company
Part number
40000
-65F (-53.8 oC) to +65F(+18.3C)
Operating temperature range
Unassisted Starting Temperature
-40F (-40C)
-65F (-53.8 oC)
Externally Assisted Starting Temperature
BTUH (maximum)
400,000
Efficiency
82%
Electrical system
24VDC
Air flow
Heated air (at 225F [1070C])
2495 ft3/minute (70.6 m3/minute)
Heater dimensions
Length
62.0 in (157.5 cm)
Width
44.5 in (113.0 cm)
Height
40.0 in (101.6 cm)
63.86 ft3 (1.80 m3)
Heater volume
Heater weight (without accessories)
622 lbs (282 kgs)
Fuel requirements:
Above +20F (-6.7C)
DF-2, DF-1, JP-8
Above -25F (-33.3C)
DF-1, JP-8
Above -60F (-51C)
JP-8
Fuel tank capacity
35 gallons (132.5 liters)
Fuel consumption
3.72 gph (14.1 lph) (at maximum heat output)
0.2 gph (0.75 lph) (in ventilation-air only mode)
Number hours continuous operation (internal tank only)
8 hours (approx)
Minimum safe distance to combustibles
2 ft (0.6 m)
Batteries
Quantity
2
Type
Sulfuric Acid, H2SO4
Rating
12VDC each
Manufacturer
Optima
NSN
0002 00-15