TM 9-4931-381-14&P-2
FRAME 14
Install Cable and Cord Assemblies (Continued):
1.
2.
3.
4.
5.
6.
Line up holes in two loop clamps (1) with holes in bracket (2).
Screw in and tighten terminal lug (3), machine screw (4) new Iockwasher (5), two
flat washers (6) and plain hexagon nut (7) with screwdriver and 11/32-inch wrench.
Screw in and tighten machine screw (8), new Iockwasher (9), flat washer (10), and
plain hexagon nut (11) with screwdriver and 1/4-inch wrench to hold tubeaxial fan
(12) to bracket (2).
Put plug (13) on fan (12).
Solder two wires (14) to switch terminals (15).
WARNING
Potting compound is toxic and extremely flammable. Use
only in welI ventiIated areas. Avoid prolonged or repeated
breathing of vapors.
Avoid prolonged contact with skin.
Keep the area free of sparks and open flames.
Put potting compound on switch terminals (15).
Follow-on Maintenance:
1. Install PCU holding fixture in accessory storage case; refer to volume 1, para. 4-
18.
2. lnstall accessory storage case cover; refer to volume 1, para. 4-18.
TASK 11 ENDS HERE
Volume IV
Para. 3-7, Task II
3-55