CONTROLS CIRCUIT BREAKER CB2 Installation
HOURMETER Installation

TM-9-4520-271-14 Improved Army Space Heater (IASH) Electric Powered Multi-fuel 140 000 BTU Model H-140 Manual
Page Navigation
  222    223    224    225    226  227  228    229    230    231    232  
TM 9-4520-271-14
0026 00
ASSEMBLY
Continued
POWER CIRCUIT BREAKER CB1 Installation
1.
Install preformed packing (8), POWER CIRCUIT BREAKER CB1 (7), two preformed packings (6), screws (5),
lockwashers (4) (item 22, WP 0062 00), and nuts (3).
2.
Connect two wires (1) with screws (2). Remove wire marker tags.
WARNING
Acrylic lacquer sealant is flammable. Keep away from open flames or other sources of ignition. Avoid
breathing fumes from sealant. Good general ventilation is normally adequate. Avoid skin contact with
sealant.
3.
Apply light coat of acrylic lacquer sealer to POWER CIRCUIT BREAKER CB1 (7) terminals.
0026 00-26