TM 10-4520-262-12&P 0037 00
UNIT MAINTENANCE
SPACE HEATER, CONVECTIVE
(NSN 4520-01-431-8927)
0037 00-1
BURNER ASSEMBLY
REMOVE, INSPECT, SERVICE, REPLACE
INITIAL SETUP
Tools
Materials/Parts
Tool Kit, General Mechanics (Item 1, WP 0044 00)
Rags, Wiping, Clean (Item 9, WP 0067 00)
Kit, Burner (Item 19, WP 0067 00)
Tags, marking, (item 6, WP 0067 00)
Personel Required
Equipment Condition
One
Heater shut down and all advisory lights off. (WP
0006 00)
In-tent controller assembly disconnected from
heater. (WP 0006 00)
Fuel source disconnected. (WP 0006 00)
Sediment Strainer emptied of fuel. (WP 0020 00)
Upper housing assembly removed. (WP 0023 00)
Battery disconnected. (WP 0018 00)
WARNING
The ignition system of this heater contains dangerous voltages which can cause severe
electrical shock. Be sure to disconnect battery pack before any maintenance actions.
WARNING
Catch and retain all residual fuel drained from disconnected conduits. Promptly wipe up
any spilled fuel. Dispose of fuel in a safe manner.
REMOVE
1. Place a petroleum absorbent mat under the burner assembly to catch any fuel that may spill.
2. Release and remove the burner to thermoelectric generator (TEG) V-clamp by loosening the two
nuts (1), opening the clamp, and moving it off the flanges between the TEG and burner assembly.