TM 10-4520-263-12&P
0019 00
0019 00-2
THIS PROCEDURE COVERS:
Heater Does Not Start or Sputters and Misfires During Operation
INITIAL SETUP:
SHS Shutdown and Cool
Maintenance Level
Materials/Parts
Unit
None
Table 1. Unit Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Heater does not start
1. Check fuel line for blockage.
Replace fuel strainer as
described in WP 0025.
2. Verify that regulating float
valve is functioning.
Replace regulating float valve
as described in WP 0024.
END OF WORK PACKAGE