TM 10-4520-263-12&P
0022 00
UNIT MAINTENANCE
SPACE HEATER SMALL (SHS)
NSN 4520-01-478-9207
OVERFLOW HOSE
REPLACE
0022 00-1
INITIAL SETUP:
REPLACE
1. To replace the overflow hose (1), squeeze the ends of the hose clamp (2) with pliers and slide the
clamp back onto the overflow hose (1). Have a petroleum absorbent mat or rag available to wipe
up any fuel that may spill.
2. Pull the overflow hose (1) from the barb fitting (3). Remove the hose clamp and set aside.
3. Slide the retained hose clamp (2) in position over the end of the new overflow hose (1).
4. Install the new overflow hose (1) onto the barb fitting (3).
5. Squeeze the hose clamp (2) ends with pliers and slide up and onto the end of the overflow hose
(1).
Tools
Personnel Required
General Mechanics Tool Kit (WP 0029 00, Table 2,
Item 1)
One
Materials/Parts
Equipment Condition
Hose, rubber (WP 0044 00, Item 1)
SHS shut-down and cool (WP 0005 00)
Mat, petroleum absorbent (WP 0049 00, Item 8)