TM 10-7310-241-12&P
2-18 Change 1
2-9. OPERATING PROCEDURES FOR MODEL RAK-15 (Continued)
OVERPRESSURE. Do not open the cover if the pressure relief
valve is making a "hissing" noise or venting steam. Set the
LO/OFF/H1 switch to OFF, wait until the noise or steam has stopped
then open the cover with extreme care using gloves or other hand
protection as necessary. Failure to comply can result in serious burn
injuries.
HIGH TEMPERATURES (1). Be aware that normal operating
temperatures within the HWR are up to 190 oF (88 oC) and can reach
higher temperatures under abnormal conditions. Always use gloves
or other hand protection as necessary. Unprotected exposure to high
temperatures can cause serious burn injuries.
(15) Using the fold-down heatproof handle (9), carefully open the cover (8) and disengage it
from the hinge pivot bar (10) located along the top rear edge of the main case (11).
(16) Holding the cover (8) by means of the fold-down heatproof handle (9), engage the latch
hook (7) with the flat center part of the folding wire handle (12) on the inner container
(13).
(17) Carefully lift out the inner container (13) together with its contents and place on a clean,
unobstructed surface so that it is standing upright in a safe position.
(18) Any heated water remaining in the outer container (14) can be dispensed by operating
the pull-action tap (17).
WARNING