TM 5-3895-377-13&P
Table 4-2. Unit Troubleshooting - CONT.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TRANSFER OIL SYSTEM (CONT)
2.
PUMP IS NOISY.
Step 1. Using a straight edge, check that pump motor sheave and pump sheave are aligned.
Align sheaves (page 4-202).
Step 2. Remove belts and turn pump by rotating sheave and check for noise.
Replace pump (page 4-196).
Step 3. With power connected, check for rotation of pump motor.
If pump motor belts are in order and pump motor works, replace pump (page 4-196).
4-46