TM 5-3895-377-13&P
Table 4-2. Unit Troubleshooting - CONT.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TRANSFER OIL SYSTEM (CONT)
3.
PUMP OUTPUT IS WEAK.
Step 1. Check for loose or leaking pipe or hose connections.
Tighten connections. If leaks do not stop, gaskets may need replacement.
Step 2. Check strainer for clogging.
Service strainer (page 4-204).
Step 3. Check speed of pump motor. Motor should operate at 1,735 RPM.
If pump operates at less than 1,700 RPM, replace pump motor (page 4-277).
4.
TRANSFER OIL DOES NOT CIRCULATE PROPERLY.
Step 1. Check strainer for clogging.
Service strainer (page 4-204).
4-47