TM 5-3895-377-13&P
5-32. CIRCULATING PUMP REPAIR (CONT).
(10) Remove split packing gland (16), two packing
gland screws (17), clips (18), and spring wire
retainer (19) from pump (15).
(11) Loosen two setscrews (20) in flange of bearing
housing (21).
(12) Using spanner wrench, remove outer end cap
(22), closure (23), and outer bearing spacer
collar (24) from bearing housing (21).
(13) Loosen two setscrews (25) in face of bearing
housing (21).
(14) While
turning
bearing
housing
(21)
counterclockwise, remove it from bracket (26).
NOTE
Inner bearing spacer collar may have
fallen out while rotor and shaft were
being removed in step (9).
(15) Remove inner bearing spacer collar (27), double
row ball bearing (28) and closure (29) from
bearing housing (21).
5-75