Section II. MOVEMENT TO NEW WORKSITE
Table 4-2. Organizational Maintenance Troubleshooting

Maintenance Manual Heater, Space, Multifuel, With Blower, 15,000 Btu/Hr, 28 Vdc Page Navigation
  13    14    15    16    17  18  19    20    21    22    23  
img
TM 5-4520-240-14
Organizational Preventive Maintenance Checks and Services
Table 4-1.
S-Semiannually
Q-Quarterly
Item to be
Procedures
Inspected
Remove top and side panels from space heater.
Housing
Assembly
Clean inside and outside of heater unit using a
dry cloth to wipe away oil, dirt, dust, fuel,
and lint.  Check fuel system for leaks, damage,
loose fittings, and loose or missing hardware.
Check electrical wiring for damage and loose
connections.  Check components for evidence of
overheating, loose hardware, and damage.
Fuel Strainer
Remove and clean fuel sediment bowl and filter
element.
Fuel Pump
Remove and clean fuel pump filter.
Filter