Figure 4-7. Side view heater showing internal components.
Figure 4-9. Fuel strainer, exploded view.

Maintenance Manual Heater, Space, Multifuel, With Blower, 15,000 Btu/Hr, 28 Vdc Page Navigation
  22    23    24    25    26  27  28    29    30    31    32  
img
.
TM 5-4520-240-14
Figure 4-8. Top view of heater showing internal components.
4-21. Fuel Strainer, Fuel Lines, and Fit-
a. Fuel Strainer Service.
tings.
(1) Disconnect the power plug and shut off the fuel
WARNING
supply. Remove the top and side cover panels to provide
The ignition system of this space
access to the fuel strainer.
heater contains dangerous voltages
(2) Loosen the nut on the fuel strainer bail. Swing
which can cause severe electrical
the bail aside and remove the fuel bowl (1, fig. 4-9),
shock. Be sure to disconnect the power
gasket (2), and filter element (3) from the fuel strainer
plug before servicing or repairing the
body (4).
heater.