Figure 10-2. Burner head components, exploded view.
Figure 10-4. Blower assembly, exploded view.

Maintenance Manual Heater, Space, Multifuel, With Blower, 15,000 Btu/Hr, 28 Vdc Page Navigation
  51    52    53    54    55  56  57    58    59    60    61  
img
TM 5-4520-240-14
k. Remove the four screws (15) and lock washers (16)
housing. Pull the heat exchanger up and out to remove
securing the heat exchanger housing (24) to the heater
it, and remove the gasket (23).
case (28). Pull out the assembled housing and heat ex-
m. If the data plates (30 and 32) are damaged, drill
changer to remove them from the case.
out the rivets (29 and 31) and remove the data plates
l. Remove the screw (17) and lock washer (18) from
from the heater case.
the underside of the heat exchanger housing (24), and
n. Disconnect the gray motor lead at the plug-in con-
remove the plate (19). Remove the five screws (20) and
nector, and disconnect the white-black lead at the
lock washers (21) securing the heat exchanger (22) to its
motor ground terminal. Remove the three screws (25)
10-3