• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SECTION XI. MAINTENANCE OF BURNER ASSEMBLY
IGNITION TRANSFORMER AND CABLE. - Continued

Maintenance Manual, Heater, Space, Multi-Fuel, With Blower, 6,000 Btu/Hr Page Navigation
  88    89    90    91    92  93  94    95    96    97    98  
img
TM 5-4520-241-14
1.
Nut
8.
Ignition cable
2.
Lock washer
9.
Igniter
3.
Washer
10.
Clamp
4.
Ignition transformer
11.
Nut
5.
Bulkhead
12.
Lock washer
6.
Brown lead
13.
Screw
7.
White lead
Figure 4-30. Ignition transformer and cable.
(5) If the ignition cable (8) only requires checking, but the ignition transformer must be replaced, unthread the
ignition cable at each end. The cable is attached to the transformer by a threaded connector and to the igniter (9) by a
threaded compression nut.
(6) If the ignition cable must be removed, disconnect clamp (10) from bulkhead (5) by removing nut (11), lock
washer (12), and screw (13). Work out of its hole the grommet that protects the ignition cable as it passes through the
heater case. The grommet is split to facilitate removal and installation. Pull out the grommet and feed the cable through
the hole.
4-77


Privacy Statement