Table 5-1. Direct Support and General Support Troubleshooting - Continued
Figure 5-3. Ventilating motor installation.

Maintenance Manual, Heater, Space, Multi-Fuel, With Blower, 6,000 Btu/Hr Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
img
. .
TM 5-4520-241-14
FIGURE 5-1
Figure 5-2. Combustion motor assembly relationships.
Table 5-1. Direct Support and General Support Troubleshooting - Continued
MALFUNCTION
TESTING OR INSPECTION
CORRECTIVE ACTION
2 - Continued
If motor fails to run, replace as follows: Remove the ventilating motor aong with its mounting
l
bracket by removing screws (1, fig. 5-3) and lock washers (2).
Remove nut (3), lock washer (4), cable clamp (5), lock washer (6), and screw (7) to unfasten one
end of grounding strap (21).
5-7