Table 5-1. Direct Support and General Support Troubleshooting - Continued
Figure 5-5. Heat exchanger insulator installation.

Maintenance Manual, Heater, Space, Multi-Fuel, With Blower, 6,000 Btu/Hr Page Navigation
  102    103    104    105    106  107  108    109    110    111    112  
img
TM 5-4520-241-14
Figure 5-4. Axial fan installation dimension.
Table 5-1. Direct Support and General Support Troubleshooting - Continued
MALFUNCTION
TESTING OR INSPECTION
CORRECTIVE ACTION
3 - Continued
Pull off the carburetor and move it out of the way. Remove the five screws that secure the burner
to the heat exchanger. Pull off the burner and gasket. Inspect the six insulators inside the burner
end of the heat exchanger. These insulators reduce the transfer of heat to the carburetor so the
fuel doesn't percolate. If insulators are in good condition, go to next step. If not, replace them.
Pull out the insulators from the end of the heat exchanger. New insulators are split to facilitate
installation.
5-10