REMARKS
ACTION
ITEM
LOCATION
INSPECTION
Replace any broken, damaged or
Inspect all parts for serviceable condition.
worn out parts with a serviceable like item.
INSTALLATION
6.
Use screws (15),
Air
washers (16),
control
nuts (17).
Install air control
(18) into casing (19)
7.
Use nuts (12) and
Air
washers (13). Install
control
baffles
four baffles (14) on
air control (18)
Use cotter pin (7).
8.
Damper
Install damper control
assembly
(11), washers (10), (9).
Install knob (8) on
damper control shaft
and secure with cotter
pin (7)
Refer to procedure 4-20
9.
Duct
and install duct
adapter
adapter and sensors
assembly
(6) and
sensors
10.
If necessary, place
Use nuts (2) and washers
(3).
cap (1) on stack
Install gasket (5)
stack
(4)
and stack (4)
4-55