3 - 1 4 . I N S T A L L A T I ON
a. Place heater in selected
needed ) or lag screws.
b.
c.
TM 5-4520-253-13
position and secure in place using 5/16-inch bolts (washers and nuts, if
Mount room thermostat in upright position on
an inside or insulated wall in the area to be
heated. Connect one end of 3-wire, 16-gauge,
shielded cable to thermostat. Refer to TEST/
ADJUST/REMOVE/lNSTALL
ROOM
THER-
MOSTAT, page 3-120.
Attach other end of cable to room thermostat
plug (3-pin).
Refer to REMOVE/lNSTALL
POWER, FUEL PUMP, AND ROOM THER-
MOSTAT PLUGS, page 3-124. Connect
assembled plug to ROOM THERMO receptacle
on side of heater control box.
3-7