TM 5-4520-253-13
A D J U S T / l N S P E C T / S E R V I C E / R E M O V E / l N S T A L L S I D E P A N E L S A N D
L O U V E R L I N K A GE
TOOLS: Tool kit, service, refrigeration unit
NSN 5180-00-596-1474
MATERIALS/PARTS: Antiseize compound (Item 1, Appendix E)
Dry cleaning solvent (Item 13, Appendix E)
GENERAL SAFETY
Power off.
Heater cool.
ADJUSTMENT:
NSTRUCTIONS:
Death or serious injury could occur it precautions are not
taken when maintaining this equipment. Position HEATER-
OFF-FAN switch to OFF, remove power cable plug from
POWER RECEPTACLE, and ground capacitors C1 and C2
prior to gaining access to heater compartments. Terminals
of capacitors are accessible at end cover of combustion
blower. Always have another person standing by who is
trained in electric shock first aid.
Remove electrical charge from ventilating air motor capaci-
tor C3 by shorting out contacts using tool having insulated
handle.
Allow sufficient time for heater to cool to room tempera-
ture before gaining access to heater compartments.
1. Side panel louvers are adjusted by a push-pull movement of louver handle (1). When louver handle
is pushed in, pivot bar (2) turns clockwise to open louvers of right-hand louver panel (3) and close
louvers of left-hand louver panel (4). Pulling on louver handle has opposite effect.
2. There is no adjustment within the linkage itself. Bent or distorted louver handle (1), pivot bar
(2), or louver linkage (5) can cause binding and improper louver action. Distorted parts must be
straightened or replaced to restore proper adjustment.
3-71