TM 9-2540-205-24&P
EQUIPMENT DATA
Hupp Models, MF510B, and MF510C, MF60A-24V, MF60B-24V
HEAT OUTPUT
High heat (HI)
54,000 to 60,000 Btu/hour
Low heat (LO)
27,000 to 33,000 Btu/hour
TEMPERATURE RISE OVER SURROUNDING AIR
(measured at heater output)
High heat (HI)
250°F (120°C) minimum
Low heat (LO)
110°F (43°C) minimum
OVERHEAT SWITCH SETTING
325° to 475°F (163° to 246°C)
FUEL REQUIREMENTS
Type
Any hydrocarbon fuel ranging from DF1, DF2,
JP8, and DFA. Fuel should conform to
MIL-G-3056 (Type ll, below 0°F) and/or
Specification W-F-800
Temperature
Pressure at fuel inlet
Consumption per minute
MF60A-24V, MF60B-24V
High heat (HI)
Low heat (LO)
MF510B, MF510C
High heat (HI)
Low heat (LO)
ELECTRICAL REQUIREMENTS
Operating voltage
Starting current
MF60A-24V, MF60B-24V
Above 30°F (-1°C)
Below 30°F (-1°C)
MF510B, MF510C
Above 30°F (-1°C)
Below 30°F (-1°C)
Running current
MF60A-24V, MF60B-24V
Above 30°F (-1°C)
Below 30°F (-1°C)
1-10
Down to cloud point of fuel or -65°F
(-54°C) when using DFA
3 to 15 psig (43.5-217.5 bars)
0.092 Ibs (41.6 g)
0.052 Ibs (23.6 g)
0.085 Ibs (38.6g) maximum
0.047 Ibs (21 .3g) maximum
20.0 to 28.5 Vdc (24Vdc nominal)
16.0 amperes
21.0 amperes
16.0 amperes
23.0 amperes
15.0 amperes
20.0 amperes