EQUIPMENT DATA - Continued
Hupp Models MF510B, and MF510C, MF60A24V, MF60B-24V -Continued
ELECTRICAL REQUIREMENTS - Continued
Running Current - Continued
MF510B, MF510C
Above 30° F (-1°C)
15.0 amperes
Below 30°F (-1°C)
20.0 amperes
DIMENSIONS
MF60A-24V, MF60B-24V
Length
24.125 inches (61.3 cm)
Width
8 inches (20.3 cm).
Height
11 inches (27.9 cm)
MF510B, MF510C
Length
27.125 inches (68.9 cm)
Width
8 inches (20.3 cm).
Height
11 inches (27.9 cm)
WEIGHT
MF510B, MF510C, MF60A-24V, MF60B-24V
32 Ibs(14.5 kg)
Stewart-Warner Models 10560C24, 10560M, 10560M24B1, and 10560G
HEAT OUTPUT
High heat (HI)
Low heat (LO)
OVERHEAT SWITCH SETTlNG
FUEL REQUIREMENTS
Type
Pressure
Consumption per minute
High heat (HI)
Low heat (LO)
TEMPERATURE RISE OVER SURROUNDING AIR
(measured at heater output)
High heat (HI)
Low heat (LO)
ELECTRICAL REQUIREMENTS
Operating voltage
Starting current
10560C24,
10560G
Above 45°F (7°C)
Below 45°F (7°C)
10560M, 10560M24B1
Above 45°F (7°C)
Below 45°F (7°C)
60,000 Btu/hr nominal
30,000 Btu/hr nominal
325 to 475°F (163 to 246°C)
DF2, DFA, JP4, JP5, JP8
3 to 15 psig (43.5 to 217.5 bars)
0.075 to 0.085 Ibs (34.0 to 38.6g)
0.041 to 0.047 Ibs (18.6 to 21.3g)
250°F (120°C) minimum
110°F (43°C) minimum
20.0 to 28.5 Vdc (24Vdc nominal)
13 amperes
17 amperes
15 amperes
20 amperes
1-11