TM 9-2540-205-24&P
VOLTAGE REGULATOR ASSEMBLY - STEWART-WARNER 10560M, 10560M24B1
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Personnel Required
TooI Kit, Mechanics Gen (Item 1, Appendix B)
63G
Key, socket-head screw, 3/32-inch
(Item 2, Appendix B)
Equipment Condition
Material/Parts
Blower assembly removed (page 3-105)
Gasket, combustion blower
Tags, marking (Item 9, Appendix C)
Tie wraps (two required) (Item 11, Appendix C)
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag all wires and terminals to aid during installation (page 2-3).
1.
2.
3.
4.
5.
6.
7.
8.
9.
Blower housing (1)
Blower housing (1) and
ventilation blower wheel (3)
Air housing (5) and
motor (6)
Motor (6) and blower
housing assembly (1)
Voltage regulator
assembly (8)
Voltage regulator
assembly (1) and air
housing (2)
Air housing (2)
Plug (2)
Setscrew (4)
Ventilation blower wheel (3)
Four screw assemblies (7)
Air housing (5)
Tie wrap (9)
Two leads (10)
Screw (3)
Voltage regulator assembly (1)
Remove.
a. Rotate wheel (3) so set-
screw (4) is in line with hole
in housing (1).
b. Unscrew part way.
Remove.
Unscrew and remove.
Remove.
a. Cut off.
b. Discard.
Remove connector.
Unscrew and remove.
Remove.
3-116