TM 9-2540-205-24&P
ORGANIZATIONAL TROUBLESHOOTING - Continued
STEWART-WARNER 10560C24, 10560M, 10560M24B1, 10560G - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. HEATER DOES NOT START - Continued
2. HEATER DOES NOT PURGE WHEN TURNED OFF
Step 1. Remove guard (page 2-42).
WARNING
The flame detector switch does not control heater temperature.
Misadjustment of flame detector switch can cause damage to the heater and
may result in Injury to personnel. Detector switch must be adjusted when
heater is cool.
Step 2. Adjust flame detector switch (page 2-44).
Step 3. Check for defective flame detector seitch (step 10, malfunction 1).
Step 4. Start and stop heater (page 2-59); wait for heater to purge.
a. if heater still does not purge, notify Direct Support Maintenance.
b. if heater purges and operates properly, install guard (page 2-42).
2-26