TM 9-2540-205-24&P
START-UP PROCEDURE - HUPP HEATERS
LOCATION
ITEM
ACTION
REMARKS
1.
2.
3.
4.
5.
6.
CAUTION
Do not hold RUN/OFF/START switch for longer than time limits given. Dam-
age to heater can result by burning out igniter or igniter control register.
Check that heater master switch is on.
Press PRESS TO TEST switch to check for
power.
Indicator light should come on.
Hold RUN/OFF/START switch at START for
Indicator light will come on when heater starts.
not longer than four minutes or until indicator
light comes on.
If heater starts, go to step 6.
Place RUN/OFF/START switch in OFF posi-
tion, and wait 15 minutes.
Hold RUN/OFF/START switch at START for
not longer than four minutes or until indicator
Indicator light will come on when heater starts.
light comes on.
If heater doss not start,
troubleshoot (page 2-15).
Place RUN/OFF/START switch in RUN posi-
tion.
TASK ENDS HERE
2-60