FUEL REGULATOR VALVE - STEWART -WARNER 10560C24, 10560M; PULSED FUEL METERING
VALVE, 1056OM24B1, 1O56OG
This task covers:
Service
INITIAL SETUP
Tools
Equipment Condition
Tool Kit, Mechanics Gen (Item 1, Appendix B)
Guard removed (page 2-42).
Materials/Parts
Container, glass, 1/2-gallon,
Hose, plastic, 5/32-inch, 1. D., 8-inch
LOCATION
ITEM
ACTION
REMARKS
SERVICE
NOTE
This service procedure applies to both fuel regulator valve and pulsed fuel metering
valve. Fuel regulator valve shown.
1. Flame detector switch (1)
Screw (2) and wire lead (3)
Unscrew and take off lead (3),
marked NO from igniter control
to flame detector switch.
2. Regulator valve (4)
Bleeder valve (5)
a. Unscrew part way.
b. Put one end of hose on bleeder
valve (5) and the other end in
glass container.
c. Hold RUN/OFF/START switch
at START.
d. Let fuel run steady into glass
container until it is clear and
bubble free.
e. Place RUN/OFF/START
switch in OFF position.
f. Take hose off bleeder valve
(5).
g. Screw in and tighten.
h. Discard fuel in container.
3. Flame detector switch (1)
Screw (2) and wire lead (3)
Screw in and tighten.
2-57