TM 9-2540-207-14&P
C1 - IGNITER FAILURE
C1
Igniter is not connected
CHECK/POSSIBLE CAUSE
REF.
REPAIR
1
Check that Igniter Hatch is installed
correctly
4.4.1
Install Igniter Hatch
Restart Heater
2
Check that Wire is Connected to
Igniter
4.4.1
Check spring washer on Igniter post.
Place wire on Post
Replace Hatch Cover
Restart Heater
3
Defective Igniter
4.4.1
Replace Igniter
Restart Heater
4
Defective Electronic
Programmed Controller Board
5.2.5
Replace Electronic Programmed Controller
Restart Heater
5
Defective Power Wiring Harness
5.5.6
Replace Power Wiring Harness
Restart Heater
6-5