TM 9-2540-207-14&P
C2 - IGNITER SHORT
C2
Igniter is not properly connected or is shorted
CHECK/POSSIBLE CAUSE
REF.
REPAIR
1
Check that Igniter Hatch is installed
correctly
4.4.1
Install Igniter Hatch Replace Igniter Wire on
Igniter Restart Heater
2
Check that Igniter wire is connected
to Igniter
4.4.1
Check spring washer on Igniter post
Place wire on Post
Replace Hatch Cover
Restart Heater
3
Defective Igniter
4.4.1
Replace Igniter
Restart Heater
4
Detective Electronic
Programmed Controller Board
5.2.5
Replace Electronic Programmed Controller
Restart Heater
5
Defective Power Wiring
Harness
5.5.6
Replace Power Wiring Harness
Restart Heater
6-6