TM 9-2540-207-14&P
C6 - VENT SENSOR FAULT
C6
Vent Thermal-Pickup circuit has failed
CHECK/POSSIBLE CAUSE
REF.
REPAIR
1
Check that Vent Sensor is connected
to the Logic Wiring Harness. Inspect
wires at connector and Vent Sensor.
5.4.2
Reconnect Vent Sensor to Logic Wiring
Harness Restart Heater
2
Defective Vent Sensor
5.4.2
Replace Vent Sensor
Restart Heater
3
Defective Logic Wiring Harness
5.5.6
Replace Logic Wiring harness
Restart Heater
4
Defective Electronic
Programmed Controller Board
5.2.5
Replace Electronic Controller Board
Restart Heater
6-10