TM 9-2540-207-14&P
F2 - BURNER FLAME OUT
F2
During Run-operations the burner temperature drops below normal operating limits
CHECK/POSSIBLE CAUSE
REF.
REPAIR
1
Check if vehicle fuel filter is
vehicle
Replace fuel filter
plugged
TM
Restart Heater
2
Check for air bubbles in the
Bleed air from fuel lines.
fuel line.
3
Check to see if fuel line
Straighten fuel lines and remove
leading to Heater is pinched or
obstructions
obstructed
Restart Heater
4
Check that there is ample fuel
Fill fuel tank with fuel
supply
Restart Heater
5
Check for obstructions in all
Remove obstructions
heater ducting
Restart Heater
6
Check for carbon build-up on
5.3.7
Clean Fuel Shaft
Burner Fuel Shaft
7
Check for Carbon
5.3
Remove carbon and clean Combustion
accumulation or obstructions
Assembly
in burner
8
Defective Flame Tube and
5.3.2
Replace Flame Tube
Burner Chamber
5.3.5
Replace Burner Chamber
9
Defective Burner Housing
5.3.7
Replace Burner Housing
Restart heater
10
Defective Fuel Injector
5.5.5
Replace Fuel Injector
Restart Heater
11
Defective Logic Wiring
5.5.6
Replace Logic Wiring Harness
Harness
Restart Heater
12
Defective Electronic
5.2.5
Replace Electronic Programmed Controller
Programmed Controller Board
Restart Heater
6-22