TM 9-4520-258-14
5-3. CONTROL BOX ASSEMBLY - continued.
e.
Installation (Refer to Figure 5-5)
(1)
Install gasket (1) (Item 14, App F), gasket (2) (Item 16, App F) and two gaskets (3) (Item 15, App F).
(2)
Insert control box assembly (4).
(3)
Install twelve flat washers (5), twelve lockwashers (6) and twelve screws (7).
(4)
Install flat washer (8), lockwasher (9), screw (10) and bar (11).
NOTE
Drain tube must be routed under the air inlet of the combustor fan assembly.
(5)
Install drain tube (12) and secure with two clamps (13).
(6)
Close control box lid (14), control panel cover (15) and door (16).
5-10