TM 9-4520-271-14
0027 00
REMOVAL
1.
Disconnect tube assembly (1), male connector (2), and reducer (3).
2.
Loosen two setscrews (4), rotate bracket (5) 45 degrees (800 mils), and remove bracket.
3.
Remove four nuts (6), lockwashers (7), washers (8), bracket (9), and gage (10). Discard lockwashers.
4.
Remove four nuts (11), lockwashers (12), eight washers (13), bracket (14), lens (15), and four screws (16). Discard
lockwashers.
0027 00-2