B - Before
A - After
M - Monthly
D - During
W - Weekly
C - Combat Operability Check
Item
Interval
Item to be
Procedures
Check for and have repaired
For Readiness Reporting
Equipment is Not
No.
B D A W M C
Inspected
or adjusted as necessary
Ready/Available if:
TM 9-4540-202-12&P
2-2. GENERAL-Continued
Table 2-1. Operator/Crew Preventive Maintenance Checks and Services - Continued
NOTE
Within designated Interval, these checks are to be performed In the order listed.
3
FUEL TANK
Check that the fuel tank is filled
with the correct fuel.
Check that the fuel tank is prop-
erly installed.
Check that fuel tank vent is in the
open position.
Inspect for leaks and spilled fuel.
Evidence of fuel leakage.
Drain the fuel tank.
4
FUEL
Check that the fuel valve controls
VALVE
the flow of fuel just below the
smoke level.
5
WATER
Inspect the water level to make
LEVEL
sure that it is six inches below the
top of the heater collar.
6
BURNER
Inspect for clean condition.
ASSEMBLY
Check that it is installed correctly
in heater body.
7
SMOKE-
Inspect for security and dean
STACK
condition.
Check that it is assembled and
installed correctly.
2-4