TM 9-4931-381-14&P-2
FRAME 44.2
Install Tranzorb:
1.
2.
3.
4.
Position new tranzorb (1) on panel assembly (2).
WARNING
Potting compound is toxic and extremely flammable. Use
only in welI ventiIated areas. Avoid prolonged or repeated
breathing of vapors.
Avoid prolonged contact with skin.
Keep the area free of sparks and open flames.
Put potting compound on tranzorb terminals (3).
CAUTION
Installing tranzorb (1) backwards can damage tranzorb (1).
Be sure to connect it as stated in step 3.
Solder wire (4) from pin 3 of S1 to pin 1 of tranzorb (1) and wire (5) from pin 6 of S1
to pin 4 of tranzorb (1).
Screw in and tighten two screws (6), four washers (7), two new Iockwashers (8), and
nuts (9) with screwdriver and wrench.
Follow-on Maintenance:
1. Install panel assembly A1; refer to task 26.
2. Install thermal system test controlIer; refer to para. 2-5, task 8.
3. Install thermal system test controller case cover; refer to volume 1, para. 4-18.
TASK 20.1 ENDS HERE
Volume IV
Para. 2-6, Task 20.1