TM 10-4500-200-13
SCREW THIS END OF ASSEMBLED VENT
TUBE INTO ADAPTER BODY WHEN
USED WITH 5 GALLON CAN
/
THREADED HOLE, FOR VENT TUBE /
INSTRUCTIONS
ASSEMBLE THE TWO PIECES OF VENT TUBE AND TIGHTEN.
FOR 5 GAL. CAN, SCREW THE PLAIN END OF ASSEMBLED
VENT TUBE INTO ADAPTER, WITH AIR HOLE AT END
FURTHEST FROM ADAPTER BODY.
3. FOR 55 GAL. DRUM, SCREW T-H-E-AIR HOLE END OF VENT
TUBE INTO ADAPTER BODY WITH PLAIN END OUT.
4 . ASSEMBLE HOSE, GASOLINE. SCREW TYPE. TO ADAPTER
KIT, GRAVITY FEED, AND TiGHTEN. `
5 . RELEASE CAM AND HOLD CAM FREE IN VERTICAL POSITION,
6. WITH CAM IN FREE POSITION, TOWARDS CAN HANDLES,
INSERT ADAPTER IN CAN.
SCREW T-HIS END
7. HOLD CAM IN FREE POSITION WITH ONE HAND TO PREVENT
OF ASSEMBLED VENT
......
ROTATION.
TUBE INTO ADAPTER
TURN PLUG BODY DOWN TIGHT TO PREVENT LEAKAGE.
BODY WHEN USED
PRESS CAM DOWN TOWARDS CAN HANDLES TO SEAL JOINTS.
8.
WITH 55 GALLON DRUM
CAUTION
A . VENT TUBE INSTALLATION
RELEASE CAM BEFORE REMOVING ADAPTER FROM CAN.
HOSE. AND DRIP
DO NOT PERMIT ADAPTER BODY TO TURN WHILE TURNING
INTERC
PLUG BODY.
INSTRUCTION
HOLD CAM STAT I
IN THIS POSITION
TIGHTENING PLU
TURN PLUG B
SEAL JOINT
B. FUEL CAN WITH ADAPTER
INSTALLED
ME 4500-200-13/3-1.1 C3
Figure 3-1.1 Fuel can adapter installation
3-2.1
Change 3