determine the amount of fuel in the bowl. When
(2) Close the latch the burner access door.
there is just enough fuel to wet the tip of the wick,
( 3 ) Turn the burner fuel line shutoff valve to
c l o s e the burner fuel line shutoff valve by turning
t h e open position.
the handwheel clockwise.
h. Move the burner air duct damper pull rod to
e. L i g h t t h e w i c k w i t h t h e f r i c t i o n i g n i t e r o r
the operating position by gradually releasing the
p u l l rod until a stable fire with proper flame has
f. Pull out the air duct damper pull rod (fig. 1-1
been established.
and 2-4) to close the burner air duct damper (which
NOTE
w i l l shut off the forced air blast to the burner) and
If the burner fails to Iight properly, relight it at
t h e n hold it in that position (fig. 2-4). Immediately
once, unless 2 minutes or more has elapsed. In this
case, fuel may be overflowing from the vaporizer
i n s e r t the lighted wick or torch into the burner pot
tube, and the burner fuel line shutoff valve must
u n t i l it contacts the bottom of the pot and ignites
be closed and no attempt must be made to relight
the fuel.
the burner for at 5 minutes. During this 5
WARNING
minutes, keep the engine running and the burner
Exercise care to keep the face away
air duct damper open to aid in evaporating the
excess fuel in the burner. After 5 minutes has
from the burner access door when
elapsed, proceed to light the burner again, using
lighting the burner.
the lighting instructions in a through h above;
g. Continue to hold the damper pull rod out and
t h e n move the burner air duct damper to
proceed as follows:
operating position.
( 1 ) Remove the torch lighter and extinguish it
b y holding the wick in or over the exhaust stack.
2-6