TM 5-3895-377-13&P
4-71.
THERMAL OVERLOAD PROTECTOR REPLACEMENT
(CONT).
NOTE
Tag and mark all wires prior to removal.
(4) Loosen three screws (9) and remove three wires (10) from thermal overload protector (11).
(5) Loosen three screws (12) and remove thermal overload protector (11) from pump motor relay (13).
b.
Installation.
(1) Install thermal overload protector (11) in pump motor relay (13) and ensure tab is seated in notch.
(2) Tighten three screws (12) in pump motor relay (13).
(3) Install three wires (10) in thermal overload protector (11) and tighten three screws (9).
4-178