TM 5-3895-377-13&P
Table 2-1. Preventive Maintenance Checks and Services - CONT.
Item
No.
Interval
Location
Item to
Check/Service
Procedure
Not Fully Mission
Capable If:
REAR OF
HEATER
WARNING
Personnel hearing can be
PERMANENTLY DAMAGED if
exposed to constant high noise
levels of 85 dB (A) or greater.
Wear approved hearing
protection devices when
working in high noise level
areas. Personnel exposed to
high noise levels shall
participate in a hearing
conservation program in
accordance with TB MED 501.
Hearing loss occurs gradually
but becomes permanent over
time.
Hearing protection is required
for operator and also for all
personnel working on or
around this Heater while it is
running.
16
Before
Exhaust Stack
Visually inspect for obvious damage.
Exhaust Stack is
obviously damaged.
17
Weekly
Valves
Add sealing compound (item 8,
appendix E) into fittings.
Visually check for leaks or obvious
Valve is damaged or
damage.
class III leak is present.
2-13