TM 5-4520-253-13
TEST PC BOARD ASSEMBLY (CONT)
Table 4-3. PC Board Testing
(6)
Meter
Indi-
cation
(1)
Component Circuit
(2)
(3)
Test For/
Meter
Setting
(4)
(5)
Probe
No. 2
Ground
Ground
Yellow Wires
(6, 7)
Yellow Wires
(6, 7)
Violet Wire
(5)
Terminal C
Ground
Ground
Ground
Probe
No. 1
Heater Mode
CIRCUIT BREAKER
Power Cable:
Plugged
Voltage
Black Wire
(1)
110Vac
CIRCUIT BREAKER
Power Cable:
Voltage
Brown Wires
Plugged
(2, 3)
Power Cable:
Resistance
Violet Wires
Unplugged
R x 1
(4, 5)
Power Cable:
Resistance
Grey Wire
Unplugged
R x 1 0
(8)
110Vac
RESET Circuit
Breaker
Zero re-
sistance
650
Ohms
RESET Circuit
Breaker
ROOM THERMO
Receptacle
Power Cable:
Plugged
Voltage
Orange Wire
(9)
Terminal A
110Vac
110Vac
HEATER-OFF-FAN
Switch: OFF
Power Cable:
Plugged
HEATER-OFF-FAN
Switch: FAN
Power Cable:
Plugged
110Vac
HEATER-OFF-FAN
Power Cable:
Voltage
Orange Wires
Switch: HEATER
Plugged
(9,11,12)
HEATER-OFF-FAN
Power Cable:
Voltage
Red Wire
Switch: OFF
Plugged
(lo)
HEATER-OFF-FAN
Power Cable:
Voltage
Orange Wires
Switch: OFF
Plugged
(9,11,12)
HEAT Indicator
Power Cable:
Voltage
Orange Wire
Light (White)
Plugged
(12)
FAULT Indicator
Power Cable:
Voltage
Violet Wire
110Vac
Ground
Zero V ac
Ground
White Wire
(13)
Zero V ac
110Vac
Yellow Wire
(7)
110Vac
Light (Red)
I Plugged
(4)
HEATER-OFF-
FAN Switch:
HEATER
Heater in
FAULT mode.
(To cause
FAULT mode,
disconnect fuel
solenoid.)
4-28
Change 2